Variants

Model
Fan size (dia.)
Motor Power
No. of blades
RPM
Air volume (CMM)
Coverage area (sq.m)
Total weight (kg)
Noise
3-Phase Drive
Voltage (V)
Current (A)
1-Phase Drive
Voltage (V)
Current (A)
Frequency (Hz)
SPYRO 12
12 ft. (3.6m)
0.75 kw (1 Hp)
5
105
1240
300
75
<38dB
415
1
230
3.26
50/60
SPYRO 16
16 ft. (4.9m)
0.75 kw (1 Hp)
5
70
10,000
600
55
<38dB
415
2.3
230
7.2
50/60
SPYRO 18
18 ft. (5.5m)
1.1 kw (1.5 Hp)
5
70
11,000
900
105
<38dB
415
3.4
230
10.8
50/60
SPYRO 20
20 ft. (6.1m)
1.1 kw (1.5 Hp)
5
60
11,500
1000
110
<38dB
415
3.4
230
10.8
50/60
SPYRO 24
24 ft. (7.3m)
1.5 kw (2 Hp)
5
55
15,500
1700
130
<38dB
415
4.7
230
14.8
50/60
ModelSPYRO 24SPYRO 20SPYRO 18SPYRO 16SPYRO 12
Fan size (dia.)24 ft. (7.3m)20 ft. (6.1m)18 ft. (5.5m)16 ft. (4.9m)12 ft. (3.6m)
Motor Power1.5 kw (2 Hp)1.1 kw (1.5 Hp)1.1 kw (1.5 Hp)0.75 kw (1 Hp)0.75 kw (1 Hp)
No. of blades55555
RPM55607070105
Air volume (CMM)15,50011,50011,00010,0001240
Coverage area (sq.m)17001000900600300
Total weight (kg)1301101055575
Noise<38dB<38dB<38dB<38dB<38dB
3-Phase Drive Voltage (v)415415415415415
3-Phase Drive Amphere (A)4.73.43.42.31
1-Phase Drive Voltage (v)230230230230230
1-Phase Drive Amphere (A)14.810.810.87.23.26
Frequency (Hz)50/6050/6050/6050/6050/60

*Note : Results of sound measurement in the field may vary due to variations in surface types, environment and conditions

ModelSPYRO 24SPYRO 20SPYRO 18SPYRO 16SPYRO 12
Fan size (dia.)24 ft. (7.3m)20 ft. (6.1m)18 ft. (5.5m)16 ft. (4.9m)12 ft. (3.6m)
Motor Power1.5 kw (2 Hp)1.1 kw (1.5 Hp)1.1 kw (1.5 Hp)0.75 kw (1 Hp)0.75 kw (1 Hp)
No. of blades55555
RPM55607070105
Air volume (CMM)15,50011,50011,00010,0001240
Coverage area (sq.m)17001000900600300
Total weight (kg)1301101055575
Noise<38dB<38dB<38dB<38dB<38dB
3-Phase Drive Voltage (v)415415415415415
3-Phase Drive Amphere (A)4.73.43.42.31
1-Phase Drive Voltage (v)230230230230230
1-Phase Drive Amphere (A)14.810.810.87.23.26
Frequency (Hz)50/6050/6050/6050/6050/60

*Note : Results of sound measurement in the field may vary due to variations in surface types, environment and conditions

High Volume Low Speed Fans

Large spaces like warehouses, railway stations, distribution centers, barns, malls, etc. have a lot more people than in houses. Air circulation in such places becomes stagnant leading to stratification of air into different layers. Smaller fans are effective when it comes to smaller spaces but large spaces require large fans that can circulate more air without affecting the humans or livestocks.

The amount of air circulated is directly proportional to the diameter and speed of the fan. If large diameter fans are used at larger speeds it can impact the occupant. Therefore, HVLS fans are used in larger spaces as they circulate large volumes of air at lower speed leading to enhanced comfort, destratification, dehumidification and unadulterated air. The Spyro HVLS Fan model was finalized after observing the effects of different numbers and types of blades in an enclosed area with various installation heights.

the benefits of installing spyro hvls fans

SYPRO HVLS Fans Major advantages OVER conventional Ceiling / Wall Mounted Fans

Particulars
Conventional Ceiling / Wall Mounted Fans
HVLS Fans
Size (Diameter)
Maximum up to 36 inches
8 feet to 24 feet
Area Coverage 15000Sq. Feet
100 Nos. Fans Required
1 Nos. Fan Required
Power Consumption per Sq. feet Area
2.5 Watt
0.1 Watt.
Air Quality
Low Volume of Air at High Speed with
Artificial Breeze Air feel
High Volume of Air at low Speed with
Natural Breeze Air feel
Noise Level
Higher
Very Low
Maintenance
High
Negligible
Initial Capital Cost
Low
High
Operating cost
High
Low
ParticularsConventional Ceiling / Wall Mounted FansHVLS Fans
Size (Diameter)Maximum up to 36 inches8 feet to 24 feet
Area Coverage 15000Sq. Feet100 Nos. Fans Required1 Nos. Fan Required
Power Consumption per Sq. feet Area 2.5 Watt0.1 Watt
Air QualityLow Volume of Air at High Speed with
Artificial Breeze Air feel
High Volume of Air at low Speed with
Natural Breeze Air feel
Noise LevelHigherVery Low
MaintenanceHighNegligible
Initial Capital CostLowHigh
Operating costHighLow

Cost Analysis

From Below table we observe

Particulars

Conventional Ceiling/Wall Mounted Fans

HVL Fans

Fan required for 15500 Sq.ft

30

1

Initial cost of fan

8000 x 30 = 2,40,000

2,20,000

Power Consumption in KWH

0.3KW x 30 = 9.0 KW/Hour

1.5 x 1 KW = 1.5 KW/Hour

ParticularsConventional Ceiling/Wall Mounted FansHVL Fans
Fan required for 15500 Sq.ft301
Initial cost of fan8000 x 30 = 2,40,0002,20,000
Power Consumption in KWH0.3KW x 30 = 9.0 KW/Hour1.5 x 1 KW = 1.5 KW/Hour

Get In Touch

If You Have Any Queries About HVLS Fans Feel Free To Contact Us !

Shopping Cart